Sample Mounting

From CLARITY Wiki

(Difference between revisions)
Jump to: navigation, search
(Thin slice mounting for confocal imaging)
(Thin slice mounting for confocal imaging)
Line 58: Line 58:
   
 
==Thin slice mounting for confocal imaging==
 
==Thin slice mounting for confocal imaging==
  +
  +
 
===Form a thin putty cylinder===
 
===Form a thin putty cylinder===
  +
Roll a piece of BluTack putty into a thin cylinder with uniform thickness. The cylinder should have a thickness about two times that of the brain sample slice.
  +
   
 
===Place putty on glass slide===
 
===Place putty on glass slide===
  +
Place the putty tube perpendicularly across the glass slide. Using a razor blade, cut off the extra puddy from outside the glass slide. Place one tube of excess puddy parallel to the first tube on the glass slide. Again, cut off the extra puddy from the second tube.
  +
   
 
===Place sample on glass slide between putty===
 
===Place sample on glass slide between putty===
  +
Carefully pipette a small amount of [[Solutions#Mounting Solution|mounting solution]] (about 10 μL) onto the glass slide between the puddy tubes, making sure it does not contact the puddy. Using a spatula and pipette tip, carefully place the sample on top of the mounting solution droplet.
  +
*''Note:'' A brain slice before clearing is shown for the purpose of demonstration
  +
   
 
===Sandwich sample with glass dish/cover slip===
 
===Sandwich sample with glass dish/cover slip===

Revision as of 04:31, 19 April 2014

Before mounting the sample for imaging, incubate the sample in the mounting solution for several hours or overnight (until the sample is visually transparent). FocusClear should be used as the mounting solution for large or whole tissue samples. Suggested methods for mounting large tissue samples (whole brain) and smaller sections (<1 mm thick brain slice) using the imaging chamber supplies are detailed below.

Contents

Whole brain mounting for confocal imaging

Form a putty cylinder

Roll a piece of BluTack putty into a cylinder with uniform thickness. The cylinder should be several centimeters in length with a thickness greater than that of the brain sample.


Place putty on a glass dish

Shape the putty cylinder into a horseshoe U shape. Place the putty onto the flat side (outside) of a Willco glass dish. Using a pipette tip, press the outside edge of the putty U down onto the glass dish to help seal it.


Place sample onto glass dish

Using a spatula, carefully place the tissue sample on the center of the dish surrounded by, but not touching, the putty. (A mouse brain before clearing is shown for the purpose of demonstration.)


Sandwich sample with second glass dish

Carefully place the flat glass side of a second Willco dish on top of the putty. Slowly press down evenly on the glass dish, keeping fingers over the putty perimeter, until the glass contacts the top of the tissue sample. Check that both glass dishes are parallel to each other.


Add FocusClear to inside of chamber

Using a pipette, add about 1-2 mL of FocusClear into the opening of the sealed chamber (apply the solution used during incubation). Fill up to the black edge of the glass dish, taking care to not introduce any bubbles into the chamber.


Apply silicone elastomer to seal chamber

Apply the Kwik-Sil PDMS sealant across the opening in the putty, making sure to cover the entire space between the glass dishes for a complete seal. Place the dishes on their side with the putty opening on top and let sit for 20 minutes to allow PDMS sealant to fully harden before imaging.


Thin slice mounting for confocal imaging

Form a thin putty cylinder

Roll a piece of BluTack putty into a thin cylinder with uniform thickness. The cylinder should have a thickness about two times that of the brain sample slice.


Place putty on glass slide

Place the putty tube perpendicularly across the glass slide. Using a razor blade, cut off the extra puddy from outside the glass slide. Place one tube of excess puddy parallel to the first tube on the glass slide. Again, cut off the extra puddy from the second tube.


Place sample on glass slide between putty

Carefully pipette a small amount of mounting solution (about 10 μL) onto the glass slide between the puddy tubes, making sure it does not contact the puddy. Using a spatula and pipette tip, carefully place the sample on top of the mounting solution droplet.

  • Note: A brain slice before clearing is shown for the purpose of demonstration


Sandwich sample with glass dish/cover slip

Add FocusClear to inside of chamber

apply silicone elastomer to seal chamber